Hitema outlines cooling systems for data centres

Hitema outlines cooling systems for data centres

Wed, 25th Nov 2026 (Today)
David Shilovsky
DAVID SHILOVSKY Interviews Editor

Hitema International has outlined its cooling systems for data centres and industrial applications. The Italian manufacturer supplies customers in more than 45 countries.

Its business centres on a fully engineered-to-order model, with each unit designed around project-specific operating conditions rather than standard catalogue formats. This approach covers cooling capacity, water temperatures, flow rates, ambient conditions, compressor choices, electrical layouts, acoustic requirements, redundancy, dimensions and control systems.

Based in Italy, Hitema has more than 35 years of experience in the sector and operates manufacturing facilities covering more than 21,000 square metres. Those sites support engineering, production, assembly and testing.

The group's product range includes air-cooled and water-cooled chillers for industrial plants, HVAC systems and data centre cooling infrastructure. Its portfolio includes oil-free magnetic-bearing Turbocor compressors as well as screw compressor systems.

Data centre focus

For data centres and other large cooling plants, Hitema's air-cooled Turbocor chillers can reach cooling capacities of up to 3 MW, while water-cooled Turbocor units can reach up to 4 MW. Some large-scale air-cooled configurations extend to about 18.3 metres in length and include up to 32 fans.

The company also highlighted its screw compressor chiller line, which reaches up to 2.5 MW in selected configurations. Options include variable-speed compressors and fans, redundant compressor architectures, automatic transfer switch systems, fast restart functions, power factor correction, high-ambient operation, low-noise versions and containerised formats.

Liquid cooling is another area of emphasis. Hitema develops Coolant Distribution Units for AI clusters, high-performance computing systems, hyperscale facilities and colocation data centres, with cooling capacities of up to 2.5 MW.

According to the company, those units are designed for direct-to-chip liquid cooling and rear-door heat exchanger installations. They use brazed plate heat exchangers, inverter-driven pumps and stainless steel hydraulic circuits, and can be configured with N+1 or 2N redundancy.

The systems are designed to integrate with Building Management Systems and Data Centre Infrastructure Management platforms for monitoring and supervision. This reflects wider demand from operators for tighter control over thermal management as computing density rises.

Testing process

Manufacturing and test procedures form a central part of the group's pitch to customers in mission-critical and industrial settings. Equipment undergoes Factory Acceptance Testing before shipment, with checks covering functional parameters, cooling performance, control logic and safety devices against project specifications.

Testing can take place with customers present on site or through remote arrangements. For more demanding operating conditions, Hitema can also carry out tests in climatic chambers to simulate high ambient temperatures, verify acoustic performance and assess optional functions such as fast restart.

The process is intended to validate equipment before delivery and reduce installation and commissioning issues. Customer-witnessed testing is also available.

North America

Hitema said North America has been part of its business for more than 30 years and remains a strategic market. The region is served through Hitema North America and Hitema Canada, which provide local support for commercial activity, technical coordination and customer service.

The company described that regional structure as a complement to its engineering and manufacturing base in Italy. The aim is to support larger projects and deliveries in industrial and data centre developments, particularly where customers require local points of contact during planning and deployment.

Hitema also provides software that allows customers, consulting engineers and partners to configure equipment, review technical options and generate technical reports and quotations. The platform covers more than 100 options across its chiller range.

The company says its business is built on designing and manufacturing equipment for the specific needs of each project rather than supplying standardised chillers.